EXTINGUSHING DEVICE CAMERA is automatic tracking and positioning jet fire extinguishing device is an
organic combination of infrared/ultraviolet sensing technology, signal processing technology, communication control technology, computer technology and mechanical transmission technology, which can automatically monitor the fire within the protection range all day. In case of fire, the device shall be started immediately, and the fire source shall be scanned in horizontal and vertical
directions. After determining the two directions of the fire source, the central controller shall send out the command, send out the fire alarm signal, start the water pump and open the valve at the same time, and the fire extinguishing device shall shoot water at the fire source to extinguish the fire, after the fire is
extinguished, the central controller sends out another command to stop the water injection. If there is a new fire source, the fire extinguishing device will repeat the above process, and return to the monitoring state after all fire sources are extinguished.
T Ein 1-Liter-Feuerlöscher ist normalerweise etwa 200 mm hoch und wiegt weniger als 1 kg.Diese Feuerlöscher werden typischerweise in kleinen Räumen verwendet, wie z. B. in Privatfahrzeugen oder kleinen Büros.
T Ein 2-Liter-Feuerlöscher ist etwas größer als ein 1-Liter-Feuerlöscher, wiegt etwa 2 bis 3 kg und ist etwa 300 mm hoch.Diese Feuerlöscher sind für den Einsatz in Haushalten und kleinen Unternehmen geeignet, wo die Brandgefahr mäßig ist.
T Ein 4-Liter-Feuerlöscher ist größer als ein 2-Liter-Feuerlöscher, wiegt etwa 4 bis 5 kg und ist etwa 400 mm hoch.Diese Feuerlöscher eignen sich für den Einsatz in größeren Haushalten oder kleinen Unternehmen, wo ein erhöhtes Brandrisiko besteht.
T 1-Liter-, 2-Liter- und 4-Liter-Feuerlöscher sind einfach zu bedienen und mit einem Manometer und einer Düse an der Oberseite ausgestattet, was eine einfache Handhabung und Handhabung im Brandfall ermöglicht.Es ist wichtig sicherzustellen, dass diese Feuerlöscher richtig platziert, leicht zugänglich und ordnungsgemäß gewartet werden, um sicherzustellen, dass sie im Brandfall einsatzbereit sind.7
T 6L FIRE EXTINGUISHER typically weighs between 11 to 14 kg and is around 500 mm tall. It is often used in areas such as factories, warehouses, and offices, where there is a higher risk of fires due to electrical equipment, flammable materials, or other potential hazards. 6L fire extinguishers are filled with Eco Fire Technology 97% water-based, and can handle fires involving flammable liquids, electrical equipment, or combustible materials such as wood or paper and all fire classes as per declaration by Eco Fire Technology.
T 9L FIRE EXTINGUISHER, on the other hand, is even larger, weighing between 14 to 17 kg and standing around 600 mm tall. These fire extinguishers are designed for more substantial fires and are typically used in industrial settings, such as chemical plants or oil refineries, where fires involving flammable liquids or gases can pose a severe threat. 9L fire extinguishers are effective in controlling and extinguishing fires involving flammable liquids, gases, and electrical equipment or combustible materials such as wood or paper and all fire classes as per declaration by Eco Fire Technology.
T Sowohl die 6-Liter- als auch die 9-Liter-FEUERLÖSCHER sind mit einem Manometer und einer Düse an der Oberseite ausgestattet, was eine einfache Handhabung und Handhabung im Brandfall ermöglicht.Es ist wichtig sicherzustellen, dass diese Feuerlöscher richtig platziert, leicht zugänglich und ordnungsgemäß gewartet werden, um sicherzustellen, dass sie im Brandfall einsatzbereit sind.
T 25-liter fire extinguisher is typically around 1200mm tall and can weigh up to 60 kg when full. These fire extinguishers are designed for use in larger spaces, such as large factories or warehouses, Gas stations etc where there is a higher risk of fire. They can handle fires involving flammable liquids, gases, and electrical equipment or combustible materials such as wood or paper and all fire classes as per declaration by Eco Fire Technology.
T 50-liter fire extinguisher is even larger, typically standing at around 1500mm tall and weighing up to 100 kg when full. These fire extinguishers are designed for use in the largest commercial and industrial spaces, such as power plants, large chemical plants, or oil refineries and high risk flammable facilities and industries that are subjected to high risks. As with other Eco Fire Technology they can handle fires involving flammable liquids, gases, and electrical equipment or combustible materials such as wood or paper and all fire classes as per declaration by Eco Fire Technology.
T Sowohl 25-Liter- als auch 50-Liter-Feuerlöscher sind mit einem Manometer und einer Düse an der Oberseite ausgestattet, was eine einfache Handhabung und Handhabung im Brandfall ermöglicht.Aufgrund ihrer Größe und ihres Gewichts sind diese Feuerlöscher typischerweise auf Rädern oder an einem festen Ort in der Einrichtung montiert.Sie müssen regelmäßig auf ihren ordnungsgemäßen Zustand überprüft und gewartet werden.
T 1000-liter Intermediate Bulk Container (IBC) with a Eco Fire Technology as liquid fire extinguishing agent is a large-capacity fire extinguisher that is commonly used in industrial and commercial settings. These IBCs are designed to hold large quantities of Eco Fire Technology fire extinguishing agents. The IBC is a large, cube-shaped container that is made of durable materials such as metal and plastic. The container is mounted on a pallet and can be transported easily using a forklift or other material handling equipment.